Views: 0 Author: Site Editor Publish Time: 2026-03-31 Origin: Site
Some customers find that after crimping, the surface of their stainless steel hose fittings starts to peel or flake.
At first glance, many think it’s a material problem. But that’s not the case.
The real cause is oxide scale left on the blank.
During forging and heat treatment, a layer of oxide scale forms on the surface of stainless steel blanks.
If this layer is not fully removed before crimping, it stays on the surface.
Crimping puts strong pressure on the fitting. The metal underneath stretches and changes shape.
But the oxide scale is brittle—it cannot stretch with the base metal. So it cracks, breaks, and peels off.
That’s the “peeling” you see.
We focus on three steps:
Strict incoming inspection
Blanks with heavy scale are rejected before they enter production.
Thorough surface cleaning
We use shot blasting and pickling to remove all oxide scale. The base metal is fully exposed.
Proper crimping control
We use precise crimping parameters. No over-crimping. This protects the surface and keeps the fitting strong.
Good control from the start helps us stop peeling before it happens.
The result: clean appearance and reliable quality.
HAND HYDRAULIC
Reliable connections you can count on.
KZE-BB 6100 Series: Threaded Hydraulic Quick Couplings That Connect Under Pressure
T-Bolt Hose Clamp: 304 Stainless Steel Heavy-Duty Clamping Guide
HAND HYDRAULIC One-Piece Hydraulic Hose Fittings: Leak-Proof Reliability for High-Pressure Systems
HAND HYDRAULIC 1CI / 1DI Metric Banjo Adapters | High Pressure Hydraulic Fittings
Hydraulic Hose Fittings | NPT / JIC / BSP / Metric / ORFS - HAND HYDRAULIC
HAND HYDRAULIC High-Profile Flange Fittings:Solve Your Hydraulic Installation Problems Easily